Artiklar


Vetenskapliga artiklar, refereegranskade

Yang, B., Melikov, A., Kabanshi, A., Zhang, C., Bauman, F., Cao, G., Awbi, H., Wigö, H., Niu, J., Cheong, K., Tham, K., Sandberg, M., Nielsen, P., Kosonen, R., Yao, R., Kato, S., Sekhar, S., Schiavon, S., Karimipanah, T., Li, X. & Lin, Z. (2019). A review of advanced air distribution methods - theory, practice, limitations and solutions. Energy and Buildings, 202. 10.1016/j.enbuild.2019.109359 [Mer information]
Sandberg, M., Kabanshi, A. & Wigö, H. (2019). Is building ventilation a process of diluting contaminants or delivering clean air?. Indoor + Built Environment. 10.1177/1420326X19837340 [Mer information]
Buccolieri, R., Sandberg, M., Wigö, H. & Di Sabatino, S. (2019). The drag force distribution within regular arrays of cubes and its relation to cross ventilation – Theoretical and experimental analyses. Journal of Wind Engineering and Industrial Aerodynamics, 189, 91-103. 10.1016/j.jweia.2019.03.022 [Mer information]
Antoniou, N., Montazeri, H., Wigö, H., Neophytou, M., Blocken, B. & Sandberg, M. (2017). CFD and wind-tunnel analysis of outdoor ventilation in a real compact heterogeneous urban area : evaluation using “air delay”. Building and Environment, 126, 355-372. 10.1016/j.buildenv.2017.10.013 [Mer information]
Buccolieri, R., Wigö, H., Sandberg, M. & Di Sabatino, S. (2017). Direct measurements of the drag force over aligned arrays of cubes exposed to boundary-layer flows. Environmental Fluid Mechanics, 17 (2), 373-394. 10.1007/s10652-016-9493-9 [Mer information]
Kabanshi, A., Wigö, H., Ljung, R. & Sörqvist, P. (2017). Human perception of room temperature and intermittent air jet cooling in a classroom. Indoor + Built Environment, 26 (4), 528-537. 10.1177/1420326X16628931 [Mer information]
Chen, L., Hang, J., Sandberg, M., Claesson, L., Di Sabatino, S. & Wigö, H. (2017). The impacts of building height variations and building packing densities on flow adjustment and city breathability in idealized urban models. Building and Environment, 118, 344-361. 10.1016/j.buildenv.2017.03.042 [Mer information]
Kabanshi, A., Wigö, H., Ljung, R. & Sörqvist, P. (2016). Experimental evaluation of an intermittent air supply system – Part 2: Occupant perception of thermal climate. Building and Environment, 108, 99-109. 10.1016/j.buildenv.2016.08.025 [Mer information]
Kabanshi, A., Wigö, H. & Sandberg, M. (2016). Experimental evaluation of an intermittent air supply system : Part 1: Thermal comfort and ventilation efficiency. Building and Environment, 95, 240-250. 10.1016/j.buildenv.2015.09.025 [Mer information]
Iqbal, A., Afshari, A., Wigö, H. & Heiselberg, P. (2015). Discharge coefficient of centre-pivot roof windows. Building and Environment, 92, 635-643. 10.1016/j.buildenv.2015.05.034 [Mer information]
Kabanshi, A., Wigö, H., Keus van de Poll, M., Ljung, R. & Sörqvist, P. (2015). The influence of heat, air jet cooling and noise on performance in classrooms. The International Journal of Ventilation, 14 (3), 321-332. 10.5555/2044-4044-14.3.321 [Mer information]
Sandberg, M., Mattsson, M., Wigö, H., Hayati, A., Claesson, L., Linden, E. & Khan, M. (2015). Viewpoints on wind and air infiltration phenomena at buildings illustrated by field and model studies. Building and Environment, 92, 504-517. 10.1016/j.buildenv.2015.05.001 [Mer information]
Iqbal, A., Wigö, H., Heiselberg, P. & Afshari, A. (2014). Effect of opening the sash of a centre-pivot roof window on wind pressure coefficients. The International Journal of Ventilation, 13 (3), 273-284. [Mer information]
Wigö, H. (2013). Effects of intermittent air velocity on thermal and draught perception : A field study in a school environment. The International Journal of Ventilation, 12 (3), 249-255. Länk [Mer information]
Wigö, H. (2008). Effects of intermittent air velocity on thermal and draught perception during transient temperature conditions. The International Journal of Ventilation, 7 (1), 59-66. 10.1080/14733315.2008.11683799 [Mer information]
Wigö, H. & Knez, I. (2005). Psychological impact of air velocity variations in a ventilated room. Ergonomics, 48 (9), 1086-1096. 10.1080/00140130500197294 [Mer information]
Wigö, H. & Nilsson, H. (2004). Application of a thermal manikin to evaluate heat loss rates from people caused by variations in air velocity and air temperature. The International Journal of Ventilation, 3 (3), 219-225. Länk [Mer information]

Doktorsavhandling

Wigö, H. (2005). Technique and human perception of intermittent air velocity variation.. Diss. (sammanfattning), 2005. Stockholm: Kungliga tekniska högskolan. 47 s. Länk [Mer information]

Konferensbidrag

Sandberg, M., Wigö, H. & Kabanshi, A. (2018). Is Building Ventilation a Process of Diluting Contaminants or Delivering Clean Air?. Excellent Indoor Climate and High Performing Ventilation. S. 253-258. Länk [Mer information]
Kabanshi, A., Sandberg, M. & Wigö, H. (2018). Measurement of Entrainment into an Axisymmetric Jet using Temperature as a Tracer : A Pilot Study. Excellent Indoor Climate and High Performing Ventilation. S. 397-402. Länk [Mer information]
Kabanshi, A., Ameen, A., Yang, B., Wigö, H. & Sandberg, M. (2017). Energy simulation and analysis of an intermittent ventilation system under two climates. 10th International Conference on Sustainable Energy and Environmental Protection : Energy Efficiency. Maribor: University of Maribor Press. S. 1-10. Länk [Mer information]
Kabanshi, A., Sattari, A., Linden, E., Wigö, H. & Sandberg, M. (2017). Experimental study on contaminant entrainment in air distribution systems with free jets. Healthy Buildings Europe 2017: ISIAQ. Länk [Mer information]
Buccolieri, R., Wigö, H., Sandberg, M. & Sabatino, S. (2017). On the drag force distribution over arrays of cubical buildings : Wind tunnel experiments. HARMO 2017 - 18th International Conference on Harmonisation within Atmospheric Dispersion Modelling for Regulatory Purposes, Proceedings: Hungarian Meteorological Service. S. 384-388. [Mer information]
Kabanshi, A. & Wigö, H. (2016). Experimental Evaluation of Intermittent Air Jet Ventilation Strategy : Cooling effect and the associated energy saving. . [Mer information]
Kabanshi, A., Wigö, H., Ljung, R. & Sorqvist, P. (2014). Perception of intermittent air velocities in classrooms. Indoor Air 2014 - 13th International Conference on Indoor Air Quality and Climate. S. 189-191. [Mer information]
Kabanshi, A., Keus van de Poll, M., Wigö, H., Ljung, R. & Sörqvist, P. (2014). The effect of heat stress on writing performance in a classroom. Indoor Air 2014 - 13th International Conference on Indoor Air Quality and Climate. S. 183-188. Länk [Mer information]
Sandberg, M., Wigö, H., Claesson, L. & Cehlin, M. (2011). A wind tunnel method for screening the interaction between wind turbines in planned wind farms. Wrec 2011 Linköping Sweden 2011. [Mer information]
Wigö, H. & Lahtimo, M. (2011). Colliding isothermal ceiling jets as a method to generate velocity variations in the occupied zone. Proc. Roomvent 2011: 12<sup>th</sup> International conference on air distribution in rooms. Trondheim, Norway.. [Mer information]
Cooper, E., Etheridge, D., Mattsson, M. & Wigö, H. (2011). Measurement of the adventitious leakage of churches with a novel pulse technique. Proc. Roomvent 2011 : 12<sup>th</sup> International conference on air distribution in rooms. Trondheim, Norge: Tapir Akademisk Forlag. [Mer information]
Lahtimo, M. & Wigö, H. (2011). Modelling of colliding isothermal jets from two ceiling diffusers. Proc. Roomvent 2011: 12<sup>th</sup> International conference on air distribution in rooms.. [Mer information]
Cooper, E., Etheridge, D., Mattsson, M. & Wigö, H. (2011). Pressure Pulse Technique – A New Method for Measuring the Leakage of the Building Envelope of Churchesmms. . [Mer information]
Sandberg, M., Neophytou, M., Fokaides, P., Panagiotou, I., Ioannou, I., Petrou, M., Wigö, H., Linden, E., Batchvarova, E., Videnov, P., Dimitroff, B. & Ivanov, A. (2011). Towards optimization of urban planning and architectural parameters for energy use minimization in Mediterranean cities. WREC 2011. [Mer information]
Buccolieri, R., Sartoretto, F., Giacometti, A., Di Sabatino, S., Leo, L., Pulvirenti, B., Sandberg, M. & Wigö, H. (2010). Flow and pollutant dispersion within the Canal Grande channel in Venice (Italy) via CFD techniques. HARMO 2010 - Proceedings of the 13th International Conference on Harmonisation within Atmospheric Dispersion Modelling for Regulatory Purposes. S. 760-764. [Mer information]
Wigö, H. (2009). Field tests of a new cooling method in a school environment. Proceedings of  11th International Conference on Air Distribution in Rooms. S. 974-978. [Mer information]
Sandberg, M., Wigö, H. & Mattsson, M. (2008). Generation of dust balls and their aerodynamic properties. Indoor air 2008 : Proceedings of the 11th International Conference on Indoor Air Quality and Climate, 17-22 August, Copenhagen, Denmark. Kgs Lyngby: Technical university of Denmark. [Mer information]
Wigö, H. (2007). Innovative cooling method in a school environment. Proceedings of the 2nd PALENC Conference and 28th AIVC Conference : building low energy cooling and advanced ventilation technologies in the 21st century, 27 - 29 September 2007, Crete Island, Greece. Aten: Heliotopos Conferences. Länk [Mer information]
Wigö, H. & Sandberg, M. (2005). Draught free intermittent cooling at moderate over temperatures by generating pulses of high velocities.. Proceedings of 10th International Conference on Indoor Air Quality and Climate. S. 209-213. 10.1111/j.1600-0668.2005.00002.x [Mer information]
Wigö, H. & Sandberg, M. (2002). Creating velocity variations in a whole room. Proceedings of the 8th International Conference on Air Distribution in Rooms. S. 273-276. [Mer information]
Wigö, H. & Sandberg, M. (2001). Velocity variations in ventilated rooms as a method for creating comfort. Proceedings of 22nd AIVC Conference. S. 27.1-27.12. [Mer information]